specifications A B L1 L2
UFC-1060-PVDF 250 170 1600 1710
UFC-1060L-PVDF 250 170 1988 2067

 

Basic parameters Component model UFC-1060-PVDF UFC-1060L-PVDF
Effective membrane area (m2) 50 75
Design water yield m3/h, 0.1MPa, 25 ℃ 2.5 3.7
Produced water turbidity NTU ﹤0.1 ﹤0.1
Component specification Shell material UPVC UPVC
Pouring form epoxy resin epoxy resin
Inlet/outlet interface DN50-ferrule joint DN50-ferrule joint
Sealing form and material O-ring/EPDM O-ring/EPDM
Equipment weight (net weight/gross weight) 45kg 65kg

 

Water inlet type

running water 

ground water 

surface water 

recycled water 

waste water 

turbidity 

﹤1 

﹤2

﹤2

﹤5

﹤15

﹤50

﹤20

﹤20

Security filtration

Optional

recommend

Design flux

90-100

80-90

70-80

70-80

60-70

50-60

50-70

20-40

rate of recovery

95%

90%

85%

80%

70%

Backwash interval

60m

30m

20m

Backwash time

60s

60s

60s

60s

60s

100s

100s

60s

Backwash pressure

0.15MPa-0.2Mpa

Backwash flow

150-200

100-150

60-100

chemical cleaning

Not recommended

Optional

recommend

 

Backwash parameters Backwashing mode Air-water backwash
Design backwash frequency 48 times/day
Scrubbing air pressure during backwashing ≤150KPa
Backwash flux 1~1.5 times of water production flux
Backwash gas flow 8~12 Nm3/h (each)
Backwash operation mode 30min per cycle
Maintenance cleaning Maintenance cleaning method Circulating flushing of low concentration citric acid or sodium hypochlorite solution
Maintenance cleaning time 50min (including flushing time)
Citric acid frequency Once/1~3 days
Sodium hypochlorite frequency Once/1~3 days
Cleaning flow 1~2m3/branch membrane module
Maintenance cleaning concentration 300 ~ 500ppm
Restorative cleaning (chemical cleaning) Chemical cleaning method Alternating circulating flushing of citric acid solution and NaOH sodium hypochlorite solution
Chemical cleaning time 90 ~ 180min
Pickling frequency Once/30~90 days/set (PH=2)
NaOH+sodium hypochlorite cleaning frequency Once/30~90 days/set (PH=10)
Circulating flow 1~3m3/formwork assembly
Chemical cleaning concentration 1000 ~ 3000ppm
Recommended temperature range of dosing detergent 20 ~ 30℃