specifications
|
A
|
B
|
L1
|
L2
|
L3
|
UFC-4040-PAN
|
90
|
99
|
931
|
959
|
1007
|
Basic parameters
|
Component model
|
UFC-4040-PAN
|
Effective membrane area(㎡)
|
3.8
|
Design water yield m3/h,0.1MPa,25℃
|
0.28
|
Produced water turbidity NTU
|
﹤1
|
Component specification
|
Shell material
|
UPVC
|
Pouring form
|
epoxy resin
|
Sealing form and material
|
O-ring/EPDM
|
Equipment weight (net weight/gross weight)
|
3.3kg/3.6kg
|
Table I Recommended parameters for flux design;
Water inlet type |
running water |
ground water |
surface water |
recycled water |
waste water |
turbidity |
﹤1 |
﹤2 |
﹤2 |
﹤5 |
﹤15 |
﹤50 |
﹤20 |
﹤20 |
Security filtration |
Optional |
recommend |
Design flux |
90-100 |
80-90 |
70-80 |
70-80 |
60-70 |
50-60 |
50-70 |
20-40 |
rate of recovery |
95% |
90% |
85% |
80% |
70% |
Backwash interval |
60m |
30m |
20m |
Backwash time |
60s |
60s |
60s |
60s |
60s |
100s |
100s |
60s |
Backwash pressure |
0.15MPa-0.2MPa |
Backwash flow |
150-200 |
100-150 |
60-100 |
chemical cleaning |
Not recommended |
Optional |
recommend |
|