specifications |
A |
B |
L2 |
L3 |
UFC-8040-PAN |
200 |
202 |
962 |
1010 |
Basic parameters |
Component model |
UFC-8040-PAN |
Effective membrane area(㎡)Measured by inner diameter |
15 |
Design water yield m3/h,0.1MPa,25℃ |
1 |
Produced water turbidity NTU |
﹤0.1 |
Component specification |
Shell material |
UPVC |
Pouring form |
epoxy resin |
Sealing form and material |
OO-ring/EPDM |
Equipment weight (net weight gross weight) |
16kg/17kg |
Table I Recommended parameters for flux design
Water inlet type |
running water |
ground water |
surface water |
recycled water |
waste water |
turbidity |
﹤1 |
﹤2 |
﹤2 |
﹤5 |
﹤15 |
﹤50 |
﹤20 |
﹤20 |
Security filtration |
Optional |
recommend |
Design flux |
90-100 |
80-90 |
70-80 |
70-80 |
60-70 |
50-60 |
50-70 |
20-40 |
rate of recovery |
95% |
90% |
85% |
80% |
70% |
Backwash interval |
60m |
30m |
20m |
Backwash time |
60s |
60s |
60s |
60s |
60s |
100s |
100s |
60s |
Backwash pressure |
0.15MPa-0.2MPa |
Backwash flow |
150-200 |
100-150 |
60-100 |
chemical cleaning |
Not recommended |
Optional |
recommend |
|